Split air conditioner Wall mounted Type Service manual R410A series
CONTENTS 2 P 1 Contents Service and Maintenance of the Air Conditioner 1 4 11 11 11 16 6 Performance Parameters Disassembly and reassembly Installation Explanations KF(R)-25GW KF(R)-35GW KF(R)-45GW KF(R)-45GW 23 23 27 31 KF(R)-25GW KF(R)-35GW KF(R)-45GW Remote controller Wiring diagram 32 21 Troubleshooting 23 Exploded views and part list KF(R)-45GW Remote controller 4 Performance Parameters
2 SERVICE AND MAINTENANCE 1 1 3 3 2 2 1 1 3 3 2 2 Air Conditioner no use for a long time. Start fan only for 3-4 hours to comple- tely dry the inside of the indoor unit. Set COOL mode or HEAT mode, and select the highest setting tempera- ture, then fan turns. Turn off air conditioner, unplug the power plug,otherwise, the accumul- ated dirt may cause fire. FAN OPERATION Take the batteries out of the remote controller. Want to use the Air Conditioner Clean filters and replace them to origi- nal position.Clean indoor unit with soft clothe. Do not use gasoline, benzene, thinner, grinding powder, detergent,insecticide etc. to clean units as they can hurt the units. Inlets and outlets of indoor and outdo- or units shall not be covered/blocked. Ground wire shall not be loose. Put in batteries, and plug the power plug.
3 1 1 4 4 3 3 2 2 1 1 4 4 3 3 2 2 Filters should be cleaned once two every weeks. Take out filters. Clean filters with a vacuum cleaner or by typing them gently. ( If they are very dirty, wash them in warm water below 45 dissolved with neutral scouring agent.) Clean filters with clean water, then dry them in cool air. Insert them at original position, then push down and close front panel. Clean deodorization filters and air cleaner. Take out filters first, then take out deodorization filter and air cleaner. Clean deodorization filter, air clean- er with warm water below 45 dissolved with neutral scouring agent. Clean filters with clean water, then dry them in cool air. Insert them at original position, then push down and close front panel. Deodorization filter, Air cleaner, Filters must be cleaned termly. Open front panel only after air conditioner stops completely. C C SERVICE AND MAINTENANCE
PERFORMANCE PARAMETERS PERFORMANCE PARAMETERS 3 1 4 2 5 6 7 The indicated noise value is from laboratories test before leaving factory. The rated cooling capacity and rated heating capacity value is tested under below conditions cooling operation heating operation indoor indoor outdoor outdoor 27 20 (DB) (DB) 35 7 (DB) (DB) 19 15 (WB) (WB) 24 6 (WB) (WB) All above should be changed without notice.There are latest and accurate specifications on the name plate of your air conditioner. During COOL mode, working temperature range is: 18 ~43 . During HEAT mode, working temperature range is:-5 ~24 . If not, the cooling and heating efficiency is not well. If air conditioner working voltage exceeds 230V 10%. it operates abnormally. Wiring diagram of air conditioner(indoor unit/outdoor unit) are attached to the unit. If the power cable or connecting cable is damaged,it must be replaced by the manufacturer or its service agent or a similar qualified person in order to avoid a hazard. NOTICE C C C C C C C C C C C C T1 220-240V , 50Hz ~ Rated cooling/heating capacity (W) Rated input (W) Rated input current(A) Dehumidifying capacity (L/h) Protection class Water-proof Refrigerant (R22) charge amount(g) Noise dB(A) Dimension(mm)WXHXD Model Function Power 3 Air flow volume(m /h) Climate type Net weight (Kg) indoor outdoor heat pump type heat pump type heat pump type indoor outdoor indoor outdoor I T1 Rated input (W) Rated cooling capacity (W) Rated input current(A) Dehumidifying capacity (L/h) Protection class Water-proof Refrigerant (R22) charge amount(g) Noise dB(A) Dimension(mm)WXHXD Model Function Power 3 Air flow volume(m /h) Climate type Net weight (Kg) indoor outdoor cool only type cool only type cool only type indoor outdoor indoor outdoor 220-240V , 50Hz ~ 220-240V , 50Hz ~ 220-240V , 50Hz ~ 220-240V , 50Hz ~ IP20(indoor) IP24(outdoor) IP20(indoor) IP24(outdoor) 220-240V , 50Hz ~ 4 2700/2800 550 1.2 38 10 285x795x180 520x770x280 34 37 11 48 42 50 1.6 600 800(Cool)/760(heat) 3.7(Cool)/3.5(heat) 5.0(Cool)/5.1(heat) 1100(Cool)/1120(heat) 3600/3850 2700 550 1.2 1.6 600 800 3.7 5.0 1100 3600 285x795x180 520x770x280 38 10 285x795x180 520x770x280 32 35 11 48 42 50 285x795x180 520x770x280 850 1190 850 1190 AUS-09H53R51A/B/C/D01 AUS-18H53RA(G)1 AUS-18C53RA(G)1 5300/5400 900 1800 2.0 48 14 46 58 1760/1720 7.81/7.63 982X198X320 860x370x690 900 1750 2.0 48 14 45 58 1750 7.81 5300 982X198X320 860x370x690 AUS-12H53R51A/B/C/D01 AUS-09C53R51A/B/C/D01 AUS-12C53R51A/B/C/D01
5 1 1 2 2 ABBREVIATION Ts: Setting Temperature Tr: Room Temperature Ti: Indoor defrost sensor temperature To: Outdoor defrost sensor temperature OPERATION OF MAIN BOARD COOL MODE If Tr > Ts, cool operation is activated. Compressor and outdoor fan are turned on. Indoor fan runs at the set speed. If Tr Ts-1 cool operation is terminated. Compressor and outdoor fan are turned off. The range of Ts is 16-31 Indoor fan speed can be adjusted for low, medium, high and auto.Compressor will be delayed for 3 minutes before it is turned on or off. C C Indoor de-ice This process is checked by the indoor defrost sensor (Ti). If Ti =2 , indoor fan increase to high speed, when Ti -1 for 1 minute continuously, compressor and outdoor fan are turn off , indoor fan increases to high speed . When Ti 8 for 5 minutes continuously, compressor and outdoor are turn on. de-ice operation is on for more than 8 minutes, system will return to normal operation. C C C AUTO CHANGEOVER MODE Per Room Temperature (RT) Cooling only type Mode PRE-SET Temperature PRE-SET Temperature Mode 24 26 RT-2 RT-2 Cool Cool Dry RT-2 RT-2 Dry Heat Heat pump type above 26 25-26 23-25 below 23 C 24 C C C C C C FAN MODE Indoor fan runs at the set speed while compressor and outdoor fan are turned off. Indoor fan speed can be adjusted for low, medium and high. When this mode is selected, the system will change from AUTO COOL to AUTO DRY to AUTO HEAT mode according to the room temperature and will run according to the programmed temperature set points as in the following table. If the unit is restarted after it is stopped for less than 2 hours, it will resume at the previously established mode before it was stopped. (i.e. AUTO COOL or AUTO DRY or AUTO HEAT) If the unit is restarted after it is stopped for more than 2 hours, it will run in a new mode according to the room temperature when it is restarted. During this mode the temperature set point can only be set + or - 2 Deg. C of the room temperature. C CONTROLS SPECIFICATION
6 Outdoor de-ice After 40 minutes of continuous heating operation, if To -4 , the outdoor de-ice operation is activated. Compressor is turned off. Indoor fan speed reduces to low speed. After 30 seconds delay, 4 way value and outdoor fan will be turned off, indoor fan reduces to low speed, 15 seconds later, the compressor is turned on and indoor fan turn off for the de-ice operation, if To 15 or 10 minutes has elapsed, the de-ice operation will be terminated. Then, the compressor is turned off. After 30 seconds delay, 4 way valve and outdoor fan are turned on, 15 seconds later, compressor and outdoor fan are turned on for return to normal operation, indoor fan is turned on for return to normal operation also. C C 4WV COMPRESSOR 30S 15S MAX 10 MINS HEAT MODE If Tr < Ts, heat operation is activated. Compressor and outdoor fan are turned on. If Tr Ts + 1 , heat operation is terminated. Compressor and outdoor fan are turned off. The range of Ts is 16 - 31 . Indoor fan speed can be adjusted for low, medium, high and auto. Compressor will delay for 3 minutes before it is turned on or off. C C Compressor will delay for 3 minutes before it is turned on or off. HEAT MODE OPT -4 15 C C DE-ICE INDOOR FAN OUTDOOR FAN 30S 15S DRY MODE If Tr 15 , dry operation is activated. Compressor and outdoor fan are turned on interval. C If Tr 23 ,. Compressor and outdoor fan are operating in sequence as follows: See A of fig1 If Tr<23 Compressor and outdoor fan are operating in sequence as follows: see B of FIG1. C C Tr 23 Tr 23 < C C OUTDOOR FAN INDOOR FAN COMPRESSOR 8mins 3mins 4mins 1min 2mins 3mins 8mins 1min 2mins 4mins 1min 1min Fig.1 A B CONTROLS SPECIFICATION
7 CONTROLS SPECIFICATION TIMER Timer off can only be set when the system is operating. Timer on can only be set when the system is off. The maximum set time is 12 hours. Changing of on/off state will cancel timer mode. HIGH PRESSURE PROTECTION If Ti > 47 , the outdoor fan is turned off. After that, if Ti < 42 , the system will start again. If Ti > 60 , the compressor is turned off. After that, if Ti < 53 , the system will start again. C C C C Compressor ON Outdoor Fan OFF Compressor ON Outdoor Fan ON Normal Operation zone Compressor ON Outdoor Fan OFF (High pressure protection) Compressor OFF Outdoor Fan OFF (High pressure protection) Compressor ON Outdoor Fan ON Normal Operation zone Temp Increasing Temp decreasing 09 type If Ti > 50 , the outdoor fan is turned off. After that, if Ti < 47 , the system will start again. If Ti > 63 , the compressor is turned off. After that, if Ti < 50 , the system will start again. C C C C 12 type If Ti > 50 , the outdoor fan is turned off. After that, if Ti < 45 , the system will start again. If Ti > 60 , the compressor is turned off. After that, if Ti < 50 , the system will start again. C C C C 18 type 47 C (09type) 50 C (12 18type) 42 C (09type) 45 C (18type) 47 C (12type) 60 C 53 C (09 12type) 50 C (18type)
8 In cool mode, if Tr-Ts < 0 , indoor fan is run at low speed. If 0 <Tr-Ts<2 , if indoor fan is running at low speed, there will be no change in speed , if fan is running at medium speed ,there will be no change in speed ,if indoor fan is run at high speed ,it will change to medium speed. If 2 <Tr-Ts<4 indoor fan keep original speed. If Tr-Ts>4 indoor fan is run at high speed. AUTO FAN SPEED C C C C 0 Tr-Ts HIGH SPEED MEDIUM SPEED LOW SPEED C 2C 4C C C In heat mode, if Tr-Ts < 1 , indoor fan is run at low speed. If 1 <Tr-Ts<3 , if indoor fan is run at low speed, there will be no change in speed , if fan run at medium speed ,there will be no change in speed , if indoor fan is run at high speed ,will change to medium speed . If 3 <Tr-Ts<5 indoor fan keep original speed. If Tr-Ts>5 indoor fan is run at high speed. C C C C 0 Tr-Ts HIGH SPEED MEDIUM SPEED LOW SPEED C 2C 4C C C CONTROLS SPECIFICATION SLEEP MODE In cool mode, after sleep mode is set, Ts will increase 1 in first hours, will increase 2 in second hours and will operation as the temperature In heat mode, after sleep mode is set, Ts will decrease 2 in first hours, will increase 2 in second hours and will operation as the temperature Changing of operation mode will cancel sleep mode. C C C C HEAT MODE COOL MODE Ts Ts-1 Ts-2 Ts Ts+1 Ts+2 1 HR 1 HR 1 HR Time C
MANUAL OPERATION BUTTON 3 3 OPERATION OF CONTROL PANEL ON INDOOR UNIT Every press of this button will turn the system on or off. SYSTEM LED LIGHT When system is operating, the RUN light is on. When system is off, the light is off. (Cool only type) Every time the switch is pressed, it changes in sequence of COOL STOP. (Heat pump type) Every time the switch is pressed, it changes in sequence of COOL HEAT STOP. MANUAL run operation procedure as the following: In the first 30 minutes operation, the compressor don't stop ,indoor fan hold high speed. After 30 minutes, emergency run operation start. Mode Setting temperature Deflector Swing Swing HEAT Fan speed High High COOL 24 C 24 C When sleep mode is operating, the SLEEP light is on. When sleep mode is off, the light is off. When timer is operating, the TIME light is on. When time is over, the light is off. CONTROLS SPECIFICATION MANUAL SWING (STEPPING MOTOR) If the indoor fan is operating, the louver will swing or can be stopped at a preferred location in any mode. The louver change location follow the order of : If a command is received, the system will respond with a beep. BUZZER 9
You're Reading a Preview
What's Included?
Lifetime Access
Fast Download Speeds
Online & Offline Access
Access PDF Contents & Bookmarks
Full Search Facility
Print one or all pages of your manual
$28.99
calcActive())">
Roadstar Split Air Conditioner Wall Mounted Type R410A Series Service Manual
Looking for detailed information on how to fix your device? Our service workshop repair manuals are the perfect solution for both professional mechanics and DIY enthusiasts. These manuals are model-specific and not generic, ensuring you have the exact information you need for your specific device.
By using these manuals, you can prevent yourself from being misled by unethical repairmen and fully understand the ins and outs of your device. The manual contains comprehensive information beneficial for every owner and user.
Upon completion of payment, the manual will be instantly available for download, eliminating the need to wait for unreliable postal delivery. Additionally, you have the flexibility to print only the pages you require, saving time and resources.
Reviews
Q&A
Recently Viewed
5,521,897Happy Clients
2,594,462eManuals
1,120,453Trusted Sellers
15Years in Business
Price:
Actual Price:
Roadstar Split Air Conditioner Wall Mounted Type R410A Series Service Manual