bhp kWb bhp kWb bhp kWb bhp kWb bhp kWb bhp kWb bhp kWb
16V-AT27GL 9:1 3600 2686 4050 3020 4500 3356
12V-AT27GL 9:1 2508 1871 2820 2104 3130 2335
8L-AT27GL 9:1 1670 1246 1880 1405 2090 1560
P9390GSI 8:1 1314 980 1478 1102 1642 1224 1970 1469
P9390GL 10.5:1 1314 980 1478 1102 1642 1224 1970 1469
P9390G 10:1 976 738 1090 813 1194 890 1366 1019
P9390G 8:1 900 671 998 744 1081 806 1216 907
L7044GSI 8:1 1120 836 1260 940 1400 1044 1680 1253
L7042GSI 8:1 985 735 1108 826 1232 919 1478 1102
L7042GL 10.5:1 985 735 1108 826 1232 919 1478 1102
L7042G 10:1 732 546 818 610 896 668 1024 764
L7042G 8:1 675 503 748 558 810 604 912 680
L5794GSI 8.2:1 920 686 1035 772 1150 858 1380 1029
L5790GSI 8.2:1 810 604 911 679 1013 755 1215 906
L5794LT 10.2:1 1205 899 1445 1078
L5774LT 10.2:1 1040 776 1250 933
L5790GL 10:1 810 604 911 679 1013 755 1215 906
F3524GSI 8:1 560 418 630 470 700 522 840 627
F3521GSI 8:1 492 367 554 413 615 459 738 550
F3521GL 10.5:1 492 367 554 413 615 459 738 550
F2895GSI 8.2:1 405 302 455 339 506 377 607 453
F2895GL 10:1 405 302 455 339 506 377 607 453
P48GSID 8.7:1 885 660 945 705 1065 800
P48GL/GLD 11:1 885 660 945 705 1065 800
L36GSID 8.7:1 670 500 710 530 800 600
L36GL/GLD 11:1 670 500 710 530 800 600
H24GSID 8.7:1 445 330 475 355 530 400
H24GL/GLD 11:1/8.7:1 445 330 475 355 530 400
F18GSID 8.7:1 335 250 355 265 400 300
F18GL/GLD 11:1/8.7:1 335 250 355 265 400 300
F11GSI/GSID 10:1 208 155 222 165 250 186
F11G 10:1 112 84 120 90 135 101
* For intermittent, reduced speed or alternate fuel power ratings, see Power Ratings Bulletin 1079 or consult Waukesha Engine, Dresser, Inc.
VSG
™
VGF
™
VHP
™
ATGL
™
130F (54C)
I.C. Water Inlet Temperature
Engine
Family Model
C.R.
(compression
ratio) 800 rpm 900 rpm 1000 rpm 1200 rpm 1500 rpm 1600 rpm 1800 rpm
POWER
RATINGS
Natural Gas Fueled
Continuous Duty Engines
G A S C O M P R E S S I O N
Waukesha Engine
Dresser, Inc.
1000 West St. Paul Avenue
Waukesha, WI 53188-4999
Phone: (262) 547-3311
Fax: (262) 549-2795
Waukesha Engine
Dresser Industrial Products, b.v.
Farmsumerweg 43
Postbus 330
9900 AH Appingedam
The Netherlands
Phone: 31-596-652222
Fax: 31-596-628111
Gulf Coast Regional Office
16701 Greenspoint Park Drive,
Suite 120
Houston, TX 77060
Phone: (281) 775-4000
Fax: (281) 775-4010
Rocky Mountain Regional Office
1228 15th Street, Suite 410
Denver, CO 80202
Phone: (720) 482-2990
Fax: (720) 482-7454
Western Canada Regional Office
#1380, 311 - 6th Avenue SW
East Tower Energy Plaza
Calgary, Alberta T2P 3H2
Phone: (403) 266-8666
Fax: (403) 265-6995
For a Distributor contact, visit our
website at:
www.waukeshaengine.dresser.com

Basic
FORMULAS
F = (C x 1.8) + 32
PREFIX
Designations
(
Number of cylinders except ATGL
which states actual number of cylinders.)
P = 16 H =8
L = 12 F =6
SUFFIX
Designations
(
G = Naturally aspirated
GSI = Turbocharged intercooled
GSID = Turbocharged intercooled draw-thru
GL = Turbocharged intercooled lean burn
LT = Lean combustion turbulence
GLD = Turbocharged intercooled lean burn
draw-thru
DISPLACEMENT
cu. in. litres
ATGL
16V-AT27GL 17398 285
12V-AT27GL 13048 214
8L-AT27GL 8699 143
VHP
P9390 9388 154
L7042/L7044 7040 116
L5790/L5794 5788 95
F3521/F3524 3520 58
F2895 2894 47
VGF
P48 2924 48
L36 2193 36
H24 1462 24
F18 1096 18
VSG
F11 673 11
kWb x 1200
RPM x Displacement (litres)
BMEP
(bar)
=
BHP x 792,000
RPM x Displacement (cubic inches)
BMEP
(psi)
=
(F-32)
1.8
C =
Application Guidelines
for Altitude and Temperature
Adjustments to Engine Systems for Natural Gas Fuels
ISO Standard/ Intermittent/
Turbocharged and Intercooled Continuous Standby
VS11G/GSI/GSID Altitude: Deduct 2% for each 1000 ft. (305 m) above: 3000 ft. 914 m 1500 ft. 457 m
Temp.: Deduct 1% for each 10F (5.5C) above: 100F 38C 100F 38C
All VGF GL/GLD/GSID Altitude: Deduct 2% for each 1000 ft. (305 m) above: 1500 ft. 457 m 1500 ft 457 m
(except GL LCR)
Deduct 6% for each 1000 ft. (305 m) above: 5000 ft. 1524 m 5000 ft. 1524 m
(F18GL LCR only)
Deduct 5% for each 1000 ft. (305 m) above: 3500 ft. 1067 m 3500 ft. 1067 m
(H24GL LCR only)
Temp.: Deduct 1% for each 10F (5.5C) above: 100F 38C 100F 38C
VHP F2895/F3521/L5790/ Altitude: Deduct 2% for each 1000 ft. (305 m) above: 6000 ft. 1828 m 1500 ft. 457 m
L7042/P9390 GSI Temp.: Deduct 1% for each 10F (5.5C) above: 100F 38C 100F 38C
VHP F3524/L5794/ Altitude: Deduct 2% for each 1000 ft. (305 m) above: 8000 ft. 2438 m 4000 ft. 1219 m
L7044 GSI* Temp.: Deduct 1% for each 10F (5.5C) above: 100F 38C 100F 38C
VHP GL Altitude: Deduct 2% for each 1000 ft. (305 m) above: 1500 ft. 457 m 1500 ft. 457 m
Temp.: Deduct 1% for each 10F (5.5C) above: 100F 38C 85F 29C
VHP L5774LT** Altitude: Deduct 2.4% for each 1000 ft. (305 m) above: 5000 ft. 1524 m
Temp.: Deduct 2.4% for each 10F (5.5C) above: 100F 38C
VHP L5794LT Altitude: Deduct 2.4% for each 1000 ft. (305 m) above: 5000 ft. 1524 m 1500 ft. 457 m
Temp.: Deduct 2.4% for each 10F (5.5C) above: 100F 38C 85F 29C
8L-AT27GL Altitude: Deduct 3.3% for each 1000 ft. (305 m) above: 3000 ft. 914 m 800 ft. 244 m
12V-AT27GL Temp.: Deduct 2% for each 10F (5.5C) above: 100F 38C 100F 38C
16V-AT27GL Compressor Altitude: Deduct 4% for each 1000 ft. (305 m) above: 6000 ft. 1828 m 6000 ft. 1828 m
(900 and 1000 rpm only***) Temp.: Deduct 2% for each 10F (5.5C) above: 100F 38C 100F 38C
16V-AT27GL EPG Altitude: Contact Waukesha Sales Engineering above: 1000 ft. 1828 m
900 rpm Temp.: Contact Waukesha Sales Engineering above: 100F 38C
16V-AT27GL EPG Altitude: Deduct 4.1% for each 1000 ft. (305 m) above: 1000 ft. 305 m 1000 ft. 305 m
1000 rpm Temp.: Deduct 3.4% for each 10F (5.5C) above: 100F 38C 100F 38C
Naturally Aspirated
All VHP/VGF/VSG G Altitude: Deduct 3% for each 1000 ft. (305 m) above: 1500 ft. 457 m 500 ft. 152 m
Temp.: Deduct 1% for each 10F (5.5C) above: 100F 38C 85F 29C
These altitude and temperature adjustments are meant to be a guide only and cannot be applied without limit. Contact Waukesha’s
Sales Engineering Department for additional information.
Unless otherwise specified, overload power is available for two hours in every 24 hour period at a level specified in the Definitions section
or on a Special Application Approval.
*The VHP3604GSI, VHP5904GSI, and VHP7104GSI models are limited to 180 F maximum jacket water temperature.
**The L5774LT is rated for 130 F intercooler water temperature only.
***For speeds other than 900 and 1000 rpm, consult the Waukesha Engine Sales Engineering Department.
Rating Standard: All models - ratings conform to ISO 3046/1 latest version with a mechanical efficiency of 90% and auxiliary
water temperature, Tcra, as specified in the Power Rating Chart, Bulletin 1079 (latest version), limited to –10 F (–5 C). Ratings
are also valid for SAE J1349, BS 5514, DIN 6271 and API 7B-11C standard atmospheric reference conditions.
Fuel Standard: All natural gas ratings are based on 900 BTU/ft
3
(35.38 MJ/m
3
[25, V(0; 101.325)]) SLHV, 91 WKI™ value
minimum, commercial quality natural gas. Refer to S-7884-7 (latest version) for full gaseous fuel specifications.
ISO Standard Power (Continuous Power Rating): The highest load and speed that can be applied 24 hours per day, seven
days per week, 365 days per year except for normal maintenance at ISO standard ambient refererence conditions. At ISO
standard ambient reference conditions, it is permissible to operate the engine at up to 110% of the ISO Standard Power or the
maximum power indicated by the intermittent rating, whichever is lower, for two hours in every 24 hour period.
ISO Service Power (Site Continuous Power Rating): The highest load and speed that can be applied 24 hours per day, seven
days per week, 365 days per year except for normal maintenance at the operating and ambient conditions of the site application.
Unless otherwise stated, it is permissible to operate the engine at up to 110% of the ISO Service Power (see the Overload Power
definition) or the intermittent power rating available at the site operating and ambient conditions, whichever is lower, for two hours
in every 24 hour period.
Overload Power: The power that an engine is permitted to supply, with a duration and frequency of use depending upon the serv-
ice application, at stated ambient conditions, immediately after operating at its ISO Service Power rating. Unless otherwise stated,
it is permissible to operate the engine at up to 110% of the ISO Service Power or the intermittent power rating available at the site
operating and ambient conditions, whichever is lower, for two hours in every 24 hour period. For situations without a defined inter-
mittent power, the allowable 10% overload power is reduced from ISO standard ambient reference conditions by the applicable rat-
ing adjustments listed in the Intermittent / Standby Power column.
Intermittent Power Rating: The highest load and speed that can be applied in variable speed mechanical system applications
only. Operation at this rating is limited to a maximum of 3500 hours per year.
Continuous Power Rating (kWe): The highest load and speed which can be applied 24 hours a day, seven days a week,
365 days per year except for normal maintenance. Unless otherwise stated, it is permissible to operate the engine at up to
110% of the generator continuous power rating for two hoursin every 24 hour period.
Standby Power Rating (kWe): This rating applies to those systems used as a secondary source of electrical power.
This rating is the output the system will produce continuously (no overload), 24 hours per day for the duration of the
prime power source outage. This rating may reduce the lifecycle intervals.
Peak Shaving Application Ratings (kWe) VHP Models Only: This rating is based on the number of horsepower hours
available per year in a constant speed application at site conditions. These ratings allow for limited engine operation above the
published ISO Standard Power rating for VHP models only. This rating class requires a Special Application Approval. Contact
Waukeshas Sales Engineering Department. This rating may reduce the lifecycle intervals.
WAUKESHA ENGINE
DRESSER, INC.
Form M4146 1/02
ATGL, VHP, VGF and VSG are trademarks/registered trademarks of Waukesha Engine, Dresser Inc. Copyright 2002 Dresser, Inc.
You're Reading a Preview
What's Included?
Fast Download Speeds
Online & Offline Access
Access PDF Contents & Bookmarks
Full Search Facility
Print one or all pages of your manual
$26.99
Viewed 37 Times Today
Loading...
Secure transaction
What's Included?
Fast Download Speeds
Online & Offline Access
Access PDF Contents & Bookmarks
Full Search Facility
Print one or all pages of your manual
$26.99
The Waukesha Gas engine Ratings for Compression application offers a range of models specifically designed for compression applications. These engines provide exceptional power and efficiency, making them perfect for various compression tasks. Whether you need to compress gas for industrial purposes or optimize natural gas production, these Waukesha gas engines deliver outstanding performance.
The models include:
- Model L7042GSI
- Model L7044GSI
- Model L7044GSI-S1
- Model VHP 9390 GSI
By purchasing this product, customers gain instant access to a downloadable link, allowing them to conveniently acquire this comprehensive engine ratings guide online.